Device Range That Can Be Set - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

12.6 Device Range that Can Be Set

The device ranges of controller that can be used for GOT
are as follows.
Note that the device ranges in the following tables are the
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ
depending on the models, even though belonging to the
same series.
Please make the setting according to the specifications of
the controller actually used.
When a non-existent device or a device number outside
the range is set, other objects with correct device settings
may not be monitored.
Setting item
Item
Set the device name, device number, and bit number.
Device
The bit number can be set only when specifying the bit of
word device.
Informati
Displays the device type and setting range which are
on
selected in [Device].
Set the monitor target of the set device.
Monitors the PLC of the specified station No.
0 to 31
: To monitor the PLC of the specified
Network
Station
100 to 115 : To specify the station No. of the PLC
No.
*1
The following shows the relation between station numbers of
the PLC and the GOT data register.
Statio
GOT data register (GD)
n No.
100
GD10
101
GD11
:
114
GD24
115
GD25
Description
station No.
to be monitored by the value of GOT
*1
data register (GD).
Setting range
0 to 31
(If setting a value
outside the range
:
above, a device
range error
occurs.)
12. CONNECTION TO LS INDUSTRIAL SYSTEMS PLC
POINT
POINT
POINT
Device settings of LS IS PLC
(1) When setting bit device (except timer and counter)
Set the bit device using the decimal number (three
digits) and the hexadecimal number.
Device name
12.6.1 LS Industrial Systems
MASTER-K
Device name
I/O relay (P)
Auxiliary relay (M)
Keep relay (K)
Link relay (L)
*1
Special relay (F)
Timer contact (T)
Counter contact (C)
I/O relay (P)
Auxiliary relay (M)
Keep relay (K)
Link relay (L)
*1
Special relay (F)
Timer current value (T)
Counter current value (C)
Step controller (S)
Data register (D)
*1
Only reading is possible.
12.6 Device Range that Can Be Set
Device number
HEX
DEC
Device
No.
Setting range
represent
ation
P0000 to P063F
M0000 to M191F
Decimal +
K0000 to K031F
Hexadeci
mal
L0000 to L063F
F0000 to F063F
T0 to T255
Decimal
C0 to C255
P000 to P063
M000 to M191
K000 to K031
L000 to L063
F000 to F063
Decimal
T0 to T255
C0 to C255
S0 to S99
D0 to D9999
12 - 13