6.4 Device Range that Can Be Set

The device ranges of controller that can be used for GOT
are as follows.
Note that the device ranges in the following tables are the
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ
depending on the models, even though belonging to the
same series.
Please make the setting according to the specifications of
the controller actually used.
When a non-existent device or a device number outside
the range is set, other objects with correct device settings
may not be monitored.
Setting item
Item
Set the device name, device number, and bit number.
Device
The bit number can be set only when specifying the bit of
word device.
Displays the device type and setting range which are
Information
selected in [Device].
Set the station number of the controller to be monitored.
Host
Select this item for monitoring the host controller.
Select this for monitoring other controllers.
Network
After selecting, set the station number of the
Other
controller to be monitored.
NW No.: Set the network No.
Station No.: Set the station No.
POINT
POINT
POINT
Device settings of YASKAWA PLC
(when using CP-9200SH, CP-9300MS, MP-920, MP-
930)
Set the coil device (MB) as follows:
(1) When setting as a bit device
Set the device using the format of word address
(DEC) + bit number (HEX).
Device name
6 - 36
6. CONNECTION TO YASKAWA PLC
6.4 Device Range that Can Be Set
Description
Device No.
Bit position (HEX)
Word address (DEC)
(2) When setting as a word device
Set the device using the format of word address
(DEC).
Device name
6.4.1
YASKAWA GL/PROGIC8
Device name
Setting range
*5
O1 to O63424
Coil (O)
*6*7
I1 to I63424
Input relay (I)
D1 to D2048
Link coil (D)
D10001 to D12048
D20001 to D22048
The bit
Setting range of each word
specification of
the word device
Input register (Z)
Z1 to Z31840
*1*7
W1 to W28291
Holding register
*2*4
(W)
SW1 to SW28291
R1 to R2048
R10001 to R12048
R20001 to R22048
Link register
*4
(R, SR)
SR1 to SR2048
SR10001 to SR12048
SR20001 to SR22048
Constant register
K1 to K4096
*3
(K)
The word
specification of
Setting range of each bit
the bit device
(except Coil,
Input relay)
*1
Change the input register "30001 to 30512" to "Z1 to Z512"
for setting. (When set in default)
*2
Change the holding register "40001 to 49999" to "W1 to
W9999" for setting. (When set in default)
*3
Change the constant register "31001 to 35096" to "K1 to
K4096" for setting. (When set in default)
*4
SR and SW indicate registers (virtual register) compatible to
Device No.
Word address (DEC)
Device No.
representation
Decimal
device
Decimal
devices
(Continued to next page)