Mitsubishi Electric GOT2000 Series Connection Manual page 319

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

(3) RS-422 connection diagram 3)
GOT side
SDA
1
SDB1
6
RDA
2
RDB
7
SG
5
RSA
3
CSA
4
RSB
8
CSB
9
*1
Connect FG grounding to the appropriate part of a cable shield line.
*2
Terminating resistor should be provided for a PLC which will be a terminal.
Precautions when preparing a cable
(1) Cable length
The length of the RS-422 cable must be 1200m or less.
(2) GOT side connector
For the GOT side connector, refer to the following.
1.4.1 GOT connector specifications
(3) GE PLC side connector
Use the connector compatible with the GE PLC side
module.
For details, refer to the GE PLC user's manual.
Connecting terminating resistors
(1) GOT side
Set the terminating resistor setting switch of the GOT
main unit to "Disable".
For the procedure to set the terminating resistor, refer
to the following.
1.4.3 Terminating resistors of GOT
(2) GE PLC side
When connecting a GE PLC to the GOT, a terminating
resistor must be connected.
GE PLC user's Manual
PLC
RT
9
RD(B')
11
RD(A')
10
SD(B)
13
SD(A)
12
SG
7
RTS(A)
6
CTS(A')
15
RTS(B)
14
CTS(B')
8
SHLD
* 1
1
* 2
terminating resistor 120Ω
PLC
* 1
11. CONNECTION TO GE PLC
11.3 Connection Diagram
RT
9
RD(B')
11
RD(A')
10
SD(B)
13
SD(A)
12
SG
7
RTS(A)
6
CTS(A')
15
RTS(B)
14
CTS(B')
8
SHLD
1
11 - 11
11