Ethernet setting for GT21
(1) Effective range of the Ethernet setting
Only [1] to [4] of the Ethernet setting can be used
for GT21. Even though [5] or later of the Ethernet
setting is written to the GT21, the setting is
disabled on the GT21 side.
(2) Range of the host station setting
Set a host station within the range of [1] to [4] of
the Ethernet setting.
Only [1] to [4]
can be used.
IP Filter Setting
To improve security, the GOT 2000 series supports the
IP Filter Setting.
For details on the IP Filter Setting, refer to the following
manual.
GT Designer3 (GOT2000) Help
6 - 24
6. CONNECTION TO YASKAWA PLC
6.3 Ethernet Connection
6.3.5
PLC side setting (MP2000
series, MP920 series)
POINT
POINT
POINT
YASKAWA PLC
For details of YASKAWA PLCs, refer to the following
manuals.
YASKAWA PLC user's Manual
Parameter settings
Make the parameter settings with a peripheral tool.
(1) Settings for 218IF-01
Item
Local IP Address
Response Time
Count of Retry
(Number of Retries)
*1
CNO
(Connection Number)
Local Port (Local
Station's Port Number)
Node IP Address
(Remote Station's IP
Parameter
*2
setting
Address)
Node Port (Remote
Station's Port Number)
Connection Type
Protocol Type
Code
Node Name (Remote
Station's Name)
Subnet Mask
Gateway IP Address
System Port No.
(Diagnostic/
Engineering Port No.)
Local Port:
TCP (Transmission
TCP/IP
Control Protocol) Zero
Setting
Window Timer Value
TCP Retry Time
TCP Close Time
IP Assemble Time
MAX. Packet Length
*1
When MITSUBISHI PLC and YASKAWA PLC are used
together in the same network, do not set the same value for
the Station of MITSUBISHI PLC and the CNO (Connection
number) of YASKAWA PLC.
*2
Set the same the Node IP Address (Remote Station's IP
Address) and the Node Port (Remote Station's Port Number)
as the Local IP Address and the Local Port (Local Station's
Port Number) on the GOT side.
For the Local IP Address and the Local Port (Local Station's
Port Number) on the GOT side, refer to the following.
6.3.3 ■ Ethernet setting
Set value
Range
PLC side IP
[ ].[ ].[ ].[ ]
address
Not required for
0
communication
with GOT
Not required for
0
communication
with GOT
1
1 to 20
10500
256 to 65534
IP address
[ ].[ ].[ ].[ ]
of GOT
Port No.
[ ]
*2
of GOT
UDP
UDP/TCP
(recommended)
Extended
MEMOBUS,
Extended
MEMOBUS,
MELSEC,
MEMOBUS
None,
MODBUS/TCP
BIN
RTU, BIN, ACII
GOT1000
Name of GOT
[ ].[ ].[ ].[ ]
[ ].[ ].[ ].[ ]
10000
PLC side
3 sec
setting
500ms
60 sec
30 sec
1500 bytes