8.6 Device Range that Can Be Set

The device ranges of controller that can be used for GOT
are as follows.
Note that the device ranges in the following tables are the
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ
depending on the models, even though belonging to the
same series.
Please make the setting according to the specifications of
the controller actually used.
When a non-existent device or a device number outside
the range is set, other objects with correct device settings
may not be monitored.
Setting item
Item
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of
word device.
Device
CPU
Set the CPU No. (1, 2) of the device to be monitored.
*2
When device B is selected, the CPU No. is fixed to 1.
No.
Information
Displays the device setting range which are selected in [Device].
Set the monitor target of the set device.
Select this item when writing data to all the
temperature controllers connected.
When bit specification of word device is performed,
data are written to the temperature controller of the
station No. set for [Host Address] of the
communication detail settings.
Monitoring and writing with bit specification of word
All
device are performed only for the station No. set for
[Host Address].
(When writing the data in numerical input, the data is
written to the connected temperature controller other
than the ones specified by the word device during
Network
input, and the temperature controller set for [Host
Address] is monitored during other than input
(displaying).)
Select this item when monitoring the temperature
controller of the specified station No.
After selecting, set the station No. in the following
range.
1 to 99
: To monitor the temperature controller
Statio
n No.
100 to 115
: To specify the station No. of the
Description
of the specified station No.
temperature controller to be monitored
by the value of GOT data register
*1
(GD).
8. CONNECTION TO YOKOGAWA TEMPERATURE CONTROLLER
*1
The following shows the relation between station numbers of
the temperature controller and the GOT data register.
Statio
GOT data register (GD)
n No.
100
GD10
101
GD11
:
:
114
GD24
115
GD25
*2
When there is no setting for the CPU No. in the
communication settings on the temperature controller side,
set the CPU No. on the GOT side to (1) (default).
8.6.1
YOKOGAWA GREEN/UT100/
UT2000/UTAdvanced
Device name
Setting range
Internal relay (I)
I0001 to I7072
The bit specification of
Setting range of each
*1
word device
the word device
*1
D0001 to D9000
Data register (D)
*1*2
B0001 to B1600
File register (B)
The word specification
Setting range of each bit
of the bit device
*1
Only 16-bit (1-word) designation is allowed.
*2
This is available only for UP750 and UP550.
8.6 Device Range that Can Be Set
Setting range
1 to 99
(If setting a value
outside the range
above, a device
range error
occurs.)
Device No.
representation
Decimal
Decimal
devices
8 - 33