Diagnostics Leds For Optical Connectors "F" (Yellow Led); Show Location - Siemens SIMATIC NET SCALANCE X-200 Operating Instructions Manual

Industrial ethernet switches
Table of Contents

Advertisement

Description of the device
3.5 The LEDs
3.5.7

Diagnostics LEDs for optical connectors "F" (yellow LED)

You will find the diagnostics LEDs only on the devices with the IRT function. With the SCALANCE
XF204-2BA IRT you will only find the diagnostics LEDs on bus adapters with SCRJ ports.
The status of the optical connectors is indicated by an additional yellow LED per connector. The
LEDs signal the following statuses:
LED color
LED status
Yellow
Lit
-
Off
3.5.8

Show Location

Localizing an IE Switches X-200
To identify an IE Switch X-200 locally and with certainty, you can use the "show location"
function on a programming device to select the node over the network and make it flash. This
can be used, for example, when assigning addresses to make sure that the correct node receives
the address. All port LEDs of the addressed node flash green at 2 Hz.
34
Meaning
Check the plug-in connection and the quality of the fiber-optic cable. If necessary, re‐
place the parts.
Relevant only if the link exists. The existing link power margin is adequate for error-free
operation.
Operating Instructions, 11/2021, C79000-G8976-C284-15
SCALANCE X-200

Advertisement

Table of Contents