Lenovo HX3510-G Installation And Service Manual page 1046

Converged hx series server
Table of Contents

Advertisement

Complete the following steps:
1. Information only; no action is required.
• I.580A4 Memory population change detected. DIMM Population Change Detected
Explanation:
Severity
Info
User Response
Complete the following steps:
1. If you have added or removed DIMMs to the system, and no additional errors were detected,
then please ignore this message.
2. Check system event log for uncorrected DIMM failures and replace those DIMMs.
• I.580A5 Mirror Fail-over complete. DIMM number [arg1] has failed over to to the mirrored copy.
DIMM Mirror Fail-over Detected
Explanation:
Severity
Info
User Response
Complete the following steps:
1. Check the system-event log for uncorrected DIMM failures and replace those DIMMs.
• I.580A6 Memory spare copy has completed successfully. Spare Copy Complete
Explanation:
Severity
Info
User Response
Complete the following steps:
1. If you have added or removed DIMMs to the system, and no additional errors were detected,
then please ignore this message.
2. Check system event log for uncorrected DIMM failures and replace those DIMMs.
• S.1100B CATERR(IERR) has asserted on processor [arg1]. Processor CATERR(IERR) has asserted
Explanation:
Severity
Error
User Response
Complete the following steps:
1034
HX3510-G, HX5510, HX5510-C, HX7510 Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx5510-cHx7510Hx5510

Table of Contents