INTERMITTENT AND POOR CONNECTION

Most intermittent are caused by faulty electrical connections or wir-
ing, although a sticking relay or solenoid can occasionally be at
fault. When checking it for proper connection, perform careful
check of suspect circuits for:
D Poor mating of connector halves, or terminals not fully seated in
the connector body (backed out).
D Dirt or corrosion on the terminals. The terminals must be clean
and free of any foreign material which could impede proper termi-
nal contact.
However, cleaning the terminal with a sand paper or the like is
prohibited.
D Damaged connector body, exposing the terminals to moisture
and dirt, as well as not maintaining proper terminal orientation
with the component or mating connector.
D Improperly formed or damaged terminals.
Check each connector terminal in problem circuits carefully to en-
sure good contact tension by using the corresponding mating ter-
minal.
If contact tension is not enough, reform it to increase contact ten-
sion or replace.
GENERAL INFORMATION 0A-15