7) When refrigerant container (3) is emptied, use following proce-
dure to replace it with a new refrigerant container (3).
a. Close low pressure valve.
b. Replace empty container (3) with a refrigerant container
which has been charged with refrigerant. When using refrig-
erant container tap valve (4), use following procedure for re-
placement.
i) Retract needle (1) and remove refrigerant container tap
valve (4) by loosening its plate nut (2).
ii) Install previously-removed refrigerant container tap valve
(4) to a new refrigerant container (3).
c. Purge any air existing in center charging hose.
When using refrigerant container tap valve, use following
procedure to purge air.
i) Once fully tighten refrigerant container tap valve and then
loosen (open) plate nut slightly.
ii) Open low pressure valve of manifold gauge set a little.
iii) As soon as refrigerant comes out with a "hiss" through a
clearance between refrigerant container and tap valve,
tighten plate nut as well as manifold gauge set low pres-
sure valve.
iv) Turn handle of tap valve clockwise so that its needle is
screwed into the new container to make a hole for refriger-
ant flow.
1. "Hiss"
AIR CONDITIONING (OPTIONAL) 1B-27