Configuration Guide - Multicast
The system view is displayed.
Step 2 Run:
interface interface-type interface-number
The interface view is displayed.
The interface can be a VLANIF interface, or an Loopback interface.
Step 3 Run:
multicast boundary group-address { mask | mask-length }
The BSR administrative domain boundary is configured. Multicast packets that belong to the
BSR administrative domain cannot traverse the boundary.
----End

7.6.4 Adjusting C-BSR Parameters

You can adjust the C-BSR parameters of the BSR administrative domain and the global domain
as required.
Context
Do as follows on all C-BSRs:
Procedure
l
Issue 01 (2011-10-26)
NOTE
The C-BSR configuration involves three cases:
l Global configuration: For global configuration, see
C-BSR. It is valid in the global domain and each BSR administrative domain.
l Configuration in a BSR administrative domain: Because the configuration in a BSR administrative
domain takes precedence over the global configuration, the global configuration is used when the
configuration in a BSR administrative domain is not done.
l Configuration in the global domain: Because the configuration in the global domain takes precedence
over the global configuration, the global configuration is used when the configuration in the global
domain is not done.
Configuration in a BSR Administrative Domain
1.
Run:
system-view
The system view is displayed.
2.
Run:
pim
The PIM view is displayed.
3.
Run:
c-bsr group group-address { mask | mask-length } [ hash-length hash-
length | priority priority ] *
The C-BSR parameters are configured.
– group-address { mask | mask-length }: specifies the range of the multicast groups
served by a C-BSR. Group addresses in the 239.0.0.0/8 are valid group addresses.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7 PIM-SM (IPv4) Configuration
Adjusting Control Parameters of the C-RP and