Huawei Quidway s3700 series Configuration Manual page 91

Hide thumbs Also See for Quidway s3700 series:
Table of Contents

Advertisement

Quidway S3700 Series Ethernet Switches
Configuration Guide - Multicast
Context
The IGMP querier can be configured globally or on an interface.
l
l
When the IGMP version is IGMPv1, the configurable parameters of the IGMP querier include
the interval for sending IGMP General Query messages and IGMP robustness variable.
Procedure
l
l
Issue 01 (2011-10-26)
The global configuration is valid on each interface.
The configuration on an interface is valid only for the specific interface. The configuration
on an interface takes precedence over the global configuration. If the IGMP querier is not
configured on the interface, the global configuration is used.
Configuring the global IGMP querier
1.
Run:
system-view
The system view is displayed.
2.
Run:
igmp
The IGMP view is displayed.
3.
Run:
timer query interval
The interval for sending IGMP General Query messages is set.
By default, the interval for sending IGMP General Query messages is 60 seconds.
4.
Run:
robust-count robust-value
The IGMP robustness variable is set.
When the S3700 starts, the S3700 sends General Query messages robust-value times.
The interval between the messages is 1/4 of the interval for sending IGMP General
Query messages. By default, the robustness variable is 2.
Configuring the IGMP querier on an interface
1.
Run:
system-view
The system view is displayed.
2.
Run:
interface interface-type interface-number
The interface view is displayed.
The S3700 uses this interface to communicate with hosts. On the S3700, VLANIF
interfaces and loopback interfaces support IGMP.
3.
Run:
igmp timer query interval
The interval for sending IGMP General Query messages is set.
By default, the interval for sending IGMP General Query messages is 60 seconds.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 IGMP Configuration
78

Advertisement

Table of Contents
loading

Table of Contents