Powering Off The Lpu; Checking The Configuration - Huawei netengine80e Configuration Manual

Hide thumbs Also See for netengine80e:
Table of Contents

Advertisement

HUAWEI NetEngine80E/40E Router
Configuration Guide - Basic Configurations
Data Preparation
To power off the LPU, you need the following data:
No.
1
2

10.5.2 Powering off the LPU

You can power off the LPU by using a command or pressing the OFL button.
Context
Do as follows on the router to be configured:
Procedure
Step 1 Run:
power
The LPU is powered off.
----End

10.5.3 Checking the Configuration

After the LPU is powered off, you can run the display device command to check whether the
LPU has been powered off.
Context
Run the following commands to check the previous configuration.
Procedure
l
----End
Issue 02 (2011-09-10)
Data
The slot number of the LPU to be powered off
A slave LPU whose board type and Physical Interface Card (PIC) type are the same
as those of the LPU to be powered off
off slot slot-id
NOTE
l To power off the sub-cards of the FPICs,
l If there is no terminal on the deployment site, you can power off the LPU by using the OFL button.
The OFL button is in the upper part of the LPU. Press the button for six seconds. If the OFL indicator
is on, it means that powering off the LPU succeeds.
Run:
display device
Check the registration of the LPU.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Run:power
off slot slot-id card card-idcommand.
10 Device Maintenance