Huawei AR200-S Series Enterprise Routers
Quick Start Guide
1: Console cable
l The 8-pin RJ45 connector is inserted into the console port (CON/AUX port) of the AR200-
l The DB9 male connector is connected to the maintenance terminal, such as a computer.
2: WAN port cable that connects the AR200-S to the upper-layer network
l On an AR201-S router, an FE port functions as the WAN port and connects to a network
l On an AR207-S router, an ADSL port functions as the WAN port and connects to a network
3: LAN port cable, which is connected to a computer with a network cable (RJ45 connectors).
4: Ground cable. The M4 connector is connected to the AR200-S and the M6 connector is
connected to ground. The cable is in yellow and green.
l When the AR200-S is placed on the desktop or installed in a cabinet/rack, the ground cable
l When the AR200-S is wall mounted, the ground cable is connected facing left, as shown
5: external power adapter, which is connected to the AC power supply to output DC power to
the device.
Power adapter output power:
l AR200-S series: 36W
NOTE

2.4 Powering on the Device

This section provides the checklist used to check the AR200-S before powering on it.
Checklist
No.
1
2
3
4
Issue 01 (2011-12-30)
S.
cable with RJ45 connectors.
cable with RJ11 connectors.
is connected facing downwards, as shown in
interfere with other devices in the cabinet/rack.
in
Figure 2-1
b.
The AC power cable must be secured using a latch.
Item
The power cables and ground cables are copper wires, and
are not spliced or damaged. The cables are safely
connected and in compliance with standards.
The power cables and ground cables are connected safely.
The spring washers of the ground cable terminals are on
the flat washer.
All signal cables to be deployed pass the continuity check. Measure
No signal cables are near the cabinet's heat vents.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Figure 2-1
a. The ground cable cannot
2 Installation Product
Method
View
View
View
15