HUAWEI NetEngine80E/40E Router
Configuration Guide - Basic Configurations
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
clock ethernet-synchronization enable
The Ethernet clock synchronization is enabled.
----End
9.7.3 Configuring Ethernet Clock Source
Context
Do as follows on all router in the clock synchronization network:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
interface interface-type interface-number
or
controller { e1 | cpos } controller-number
The interface view is displayed.
Step 3 Run:
clock synchronization enable
The Ethernet clock synchronization function is enabled.
Step 4 Run:
clock [ 2msync-1 | 2msync-2 ] priority priority-value
The priority of the clock reference source is configured.
Step 5 Run:
clock ssm { dnu | prc | sec | ssua | ssub | unk }
The SSM level of the clock source is configured.
----End
9.7.4 Checking the Configuration
Context
Run the following commands to check the previous configuration.
Issue 02 (2011-09-10)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
9 Clock Synchronization Configuration
245