HUAWEI NetEngine80E/40E Router
Configuration Guide - Basic Configurations
l
l
l
l
l
l
l
l
l
Procedure
Step 1 Set physical attributes of the AUX user interface.
<HUAWEI> system-view
[HUAWEI] user-interface aux 0
[HUAWEI-ui-aux0] speed 9600
[HUAWEI-ui-aux0] flow-control none
[HUAWEI-ui-aux0] parity none
[HUAWEI-ui-aux0] stopbits 1
[HUAWEI-ui-aux0] databits 8
All the preceding physical attributes of the AUX user interface are set with default values. In
fact, if a user chooses to use the default values, the user does not need to set them. The preceding
settings only mean to provide the configuration method.
Step 2 Set terminal attributes of the AUX user interface.
[HUAWEI-ui-aux0] shell
[HUAWEI-ui-aux0] idle-timeout 30
[HUAWEI-ui-aux0] screen-length 30
[HUAWEI-ui-aux0] history-command max-size 20
Step 3 Set the user priority of the AUX user interface.
[HUAWEI-ui-aux0] user privilege level 15
Step 4 Set modem attributes of the AUX user interface.
[HUAWEI-ui-aux0] modem timer answer 45
[HUAWEI-ui-aux0] modem call-in
[HUAWEI-ui-aux0] modem auto-answer
Step 5 Set the authentication mode of the AUX user interface to AAA.
[HUAWEI-ui-aux0] authentication-mode aaa
[HUAWEI-ui-aux0] quit
[HUAWEI] aaa
[HUAWEI-aaa] local-user user123 password simple huawei
[HUAWEI-aaa] quit
After the AUX user interface is configured, a user in AAA authentication mode can log in to
the router through an AUX port, implementing maintenance of the router. For details on how a
user logs in to the router, refer to the
----End
Configuration Files
#
sysname HUAWEI
Issue 02 (2011-09-10)
Parity of the AUX user interface: None
Stop bit of the AUX user interface: 1
Data bit of the AUX user interface: 8
Timeout period for disconnecting from the AUX user interface: 30 minutes
Number of lines that a terminal screen displays: 30
Size of the history command buffer: 20
User priority: 15
Modem attributes: idle timeout from off-hook to carrier detection (45 seconds), call-in
permission, and automatic response
User authentication mode and password in the AUX user interface
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 Configuring User
Login.
4 Configuring User Interface