Context
Physical attributes of the AUX user interface have default values on the router and no additional
configuration is needed.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
user-interface
The AUX user interface view is displayed.
Step 3 Run:
speed
The transmission rate is set.
By default, the baud rate is 9600 bit/s.
Step 4 Run:
flow-control
The flow control mode is set.
By default, the flow-control mode is none.
Step 5 Run:
parity
The parity mode is set.
By default, the value is none.
Step 6 Run:
stopbits
The stop bit is set.
By default, the value is 1 bit.
Step 7 Run:
databits
The data bit is set.
By default, the value is 8.
----End