Huawei netengine80e Configuration Manual page 75

Hide thumbs Also See for netengine80e:
Table of Contents

Advertisement

HUAWEI NetEngine80E/40E Router
Configuration Guide - Basic Configurations
Configuration Roadmap
The configuration roadmap is as follows:
1.
2.
3.
4.
Data Preparation
To complete the configuration, you need the following data:
l
l
l
l
l
l
l
l
l
l
Procedure
Step 1 Set physical attributes of the console user interface.
<HUAWEI> system-view
[HUAWEI] user-interface console 0
[HUAWEI-ui-console0] speed 4800
[HUAWEI-ui-console0] flow-control none
[HUAWEI-ui-console0] parity even
[HUAWEI-ui-console0] stopbits 2
[HUAWEI-ui-console0] databits 6
Step 2 Set terminal attributes of the console user interface.
[HUAWEI-ui-console0] shell
[HUAWEI-ui-console0] idle-timeout 30
[HUAWEI-ui-console0] screen-length 30
[HUAWEI-ui-console0] history-command max-size 20
Step 3 Set the user priority of the console user interface.
[HUAWEI-ui-console0] user privilege level 15
Step 4 Set the user authentication mode in the console user interface to password.
[HUAWEI-ui-console0] authentication-mode password
[HUAWEI-ui-console0] set authentication password simple huawei
[HUAWEI-ui-console0] quit
After the console user interface is configured, a user in password authentication mode can log
in to the router through a console port, implementing local maintenance of the router. For details
on how a user logs in to the router, see the
----End
Issue 02 (2011-09-10)
Enter the interface view and set physical attributes of the console user interface.
Set terminal attributes of the console user interface.
Set the user priority of the console user interface.
Set the user authentication mode and password of the console user interface.
Transmission rate of the console user interface: 4800 bit/s
Flow control mode of the console user interface: None
Parity of the console user interface: even
Stop bit of the console user interface: 2
Data bit of the console user interface: 6
Timeout period for disconnecting from the console user interface: 30 minutes
Number of lines that a terminal screen displays: 30
Size of the history command buffer: 20
User priority: 15
User authentication mode: password (password: huawei)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 Configuring User
Login.
4 Configuring User Interface
60

Advertisement

Table of Contents
loading

This manual is also suitable for:

Netengine40e

Table of Contents