Controlling The Signal Contact; Monitoring The Device Status Via The Signal Contact - Hirschmann RS20 User Manual

Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Operation Diagnosis
9.3.1

Controlling the Signal Contact

With this mode you control this signal contact remotely.
Application options:
Simulation of an error detected during SPS error monitoring
Remote control of a device via SNMP, such as switching on a camera
 Select the Diagnostics:Signal Contact 1/2) dialog.
 In the "Mode Signal contact" frame, you select the "Manual setting"
mode to switch the contact manually.
 Select "Opened" in the "Manual setting" frame to open the contact.
 Select "Closed" in the "Manual setting" frame to close the contact.
enable
configure
signal-contact 1 mode manual Select the manual setting mode for signal contact
signal-contact 1 state open
signal-contact 1 state close Close signal contact 1.
9.3.2
Monitoring the Device Status via the Signal
Contact
The "Device Status" option enables you, like in the operation monitoring, to
monitor the device state
via the signal contact.
UM BasicConfig L2E
Release 8.0 05/2013
Switch to the privileged EXEC mode.
Switch to the Configuration mode.
1.
Open signal contact 1.
(see on page 163 "Monitoring the Device Status")
9.3 Out-of-band Signaling
167