Loading/saving settings
Note: After you have successfully saved the configuration on the device, the
device sends a trap hmConfigurationSavedTrap together with the
information about the AutoConfiguration Adapter (ACA), if one is connected.
When you change the configuration for the first time after saving it, the device
sends a trap hmConfigurationChangedTrap.
Note: The device allows you to trigger the following events when the
configuration stored on the ACA does not match the configuration on the
device:
send a trap
(see on page 161 "Configuring
update the device status
Status"),
update the status of the signal contacts
Signal
Contact").
Skip ACA21 during the boot phase
The device allows you to skip the ACA21 AutoConfiguration Adapter (if
connected) during the boot phase. In this case, the device ignores the
ACA21 during the boot phase. This shortens the boot phase of the device
by 1 to 4 seconds. If you have enabled this function, ACA21-functionality
becomes available as usual after the boot phase. The device simply skips
the ACA21-loading procedures during the boot phase.
enable
configure
#boot skip-aca-on-boot
enable
#boot skip-aca-on-boot
disable
#show boot skip-aca-
on-boot
UM BasicConfig L2E
Release 8.0 05/2013
(see on page 164 "Configuring the Device
(see on page 167 "Controlling the
Switch to Privileged EXEC mode..
Switch to Global Configure mode.
Skip ACA during the boot phase.
(default setting: disabled).
Include the ACA during the boot phase.
Show whether the "Skip ACA during boot phase"function
is enabled.