Configuring the Ports
Switch on PoE power supply
OCTOPUS PoE devices let you switch on the PoE power supply before
loading and starting the software. This means that the connected PoE
devices (powered devices) are supplied with the PoE voltage more
quickly and the start phase of the whole network is shorter.
enable
configure
#inlinepower fast-startup
enable
#inlinepower fast-startup
disable
#show inlinepower
Cold start with detected errors
This function lets you reset the device automatically with a cold start in the
following cases:
if an error is detected
(selftest reboot-on-error enable)
or
only if a serious error is detected
(selftest reboot-on-error seriousOnly)
If the function selftest reboot-on-error seriousOnly is
enabled, the device behaves as follows:
If an error is detected in a subsystem (for example, if an HDX/FDX
mismatch is detected on a port), cold starts of the device are dropped.
However, if an error affecting the function of the entire device is
detected, the device still carries out a cold start.
The device sends a trap
Note: If the selftest reboot-on-error seriousOnly function is
enabled and the device detects an HDX/FDX mismatch, automatic cold
starts of the device are dropped. In this case, to return the affected port(s)
to a usable condition, open the Basic Settings:Reboot dialog and
carry out a cold start of the device.
enable
configure
UM BasicConfig L2E
Release 8.0 05/2013
Switch to Privileged EXEC mode.
Switch to Global Configure mode.
Switch on Inline Power Fast Startup (disabled in
the as-delivered state).
Switch off Inline Power Fast Startup.
Show Power over Ethernet System Information
(Fast Startup and other information).
(see on page 158 "Sending
Switch to Privileged EXEC mode.
Switch to Global Configure mode.
Traps").