Loading/saving settings

3.2 Saving settings

In the "Save" frame, you have the option to
save the current configuration on the device,
save the current configuration in binary form in a file under the specified
URL,
save the current configuration in binary form on the PC,
save the current configuration for the offline configurator on the PC in
XML format.
3.2.1

Saving locally (and on the ACA)

The device allows you to save the current configuration data in the local non-
volatile memory and in the ACA.
 Select the
Basics: Load/Save dialog.
 In the "Load" options, click on "From device".
 Click on "Save".
The device saves the current configuration data in the local non-
volatile memory and also, if a ACA is connected, in the ACA.
enable
copy system:running-config
nvram:startup-config
60
Switch to the privileged EXEC mode.
The device saves the current configuration data
in the local non-volatile memory and also, if a
ACA is connected, in the ACA
3.2 Saving settings
UM BasicConfig L2E