Network Load Control
Note: The devices RS20/30/40, MS20/30, Octopus, MACH 100, RSR
and MACH 1000 do not support flow control in half duplex mode.
8.5.2

Setting the Flow Control

 Select the
Basics:Port Configuration dialog.
In the "Flow Control on" column, you checkmark this port to specify
that flow control is active here. You also activate the global "Flow
Control" switch in the
Switching:Global dialog.
 Select the Switching:Global dialog.
With this dialog you can
switch off the flow control at all ports or
switch on the flow control at those ports for which the flow control is selected in
the port configuration table.
Note: When you are using a redundancy function, you deactivate the flow
control on the participating device ports. If the flow control and the
redundancy function are active at the same time, there is a risk that the
redundancy function will not operate as intended.
142
8.5 Flow Control
UM BasicConfig L2E
Release 8.0 05/2013