For every supply voltage to be connected, perform the following steps:
Pull the terminal block off the device.
Connect the wires according to the pin assignment on the device with the
clamps.
Fasten the wires connected by tightening the terminal screws.
With a non-redundant supply of the supply voltage, the device reports the
loss of a supply voltage. You can prevent this message by changing the
configuration in the Management.
2.4.4
Signal contact
Proceed as follows:
Connect the signal contact lines with the terminal block connections.
Fasten the wires connected by tightening the terminal screws.
2.5
Mounting a terminal block
Proceed as follows:
Mount the terminal block for the voltage supply and signal contact on the
front of the device using the snap lock. Verify that the snap lock latches in
place.
2.6
Operating the device
Proceed as follows:
By connecting the supply voltage via the terminal block, you start the
operation of the device.
48
Installation RSR20/RSR30
Release 04 10/2015