Configuring The Device Status - Hirschmann RS20 User Manual

Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Operation Diagnosis
Select the corresponding entries to decide which events the device status
includes.
Note: With a non-redundant voltage supply, the device reports the absence
of a supply voltage. If you do not want this message to be displayed, feed the
supply voltage over both inputs or switch off the monitoring
"Monitoring the Device Status via the Signal
9.2.1

Configuring the Device Status

 Open the
 In the "Monitoring" field, you select the events you want to monitor.
 To monitor the temperature, you also set the temperature thresholds
in the Basic settings:System dialog at the end of the system
data.
enable
configure
device-status monitor all
error
device-status trap enable
Note: The above CLI commands activate the monitoring and the trapping
respectively for all the supported components. If you want to activate or
deactivate monitoring only for individual components, you will find the
corresponding syntax in the CLI manual or in the help of the CLI console
(enter a question mark "?" at the CLI prompt).
164
Diagnostics:Device Status
9.2 Monitoring the Device Status
Contact").
dialog.
Switch to the privileged EXEC mode.
Switch to the Configuration mode.
Include all the possible events in the device
status determination.
Enable a trap to be sent if the device status
changes.
(see on page 167
UM BasicConfig L2E
Release 8.0 05/2013