Hirschmann RS20 User Manual page 162

Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Operation Diagnosis
The events which can be selected are:
Name
Meaning
Authentication The device has rejected an unauthorized access attempt (see the Access
for IP Addresses and Port Security dialog).
Link Up/Down At one port of the device, the link to another device has been
established/interrupted.
Spanning Tree The topology of the Rapid Spanning Tree has changed.
Chassis
Summarizes the following events:
– The status of a supply voltage has changed (see the System dialog).
– The status of the signal contact has changed.
To take this event into account, you activate "Create trap when status
changes" in the Diagnostics:Signal Contact 1/2 dialog.
- The AutoConfiguration Adapter (ACA), has been added or removed.
- The configuration on the AutoConfiguration Adapter(ACA) does not
match that in the device.
– The temperature thresholds have been exceeded/not reached.
– A media module has been added or removed (only for modular devices).
– The receiver power status of a port with an SFP module has changed
(see dialog Diagnostics:Ports:SFP Modules).
The redundancy status of the ring redundancy (redundant line
active/inactive) or (for devices that support redundant ring/network
coupling) the redundant ring/network coupling (redundancy exists) has
changed.
Port security
On one port a data packet has been received from an unauthorized
terminal device (see the Port Security dialog).
Table 19: Trap categories