Operation diagnosis
Note: With non-redundant voltage supply, the Switch reports the absence of
a supply voltage. You can prevent this message by feeding the supply volt-
age over both inputs, or by switching off the monitoring
"Monitoring correct operation via the signal

9.2.1 Configuring the device status

Select the Diagnostics:Device Status dialog.
In the "Monitoring" field, you select the events you want to monitor.
To monitor the temperature, you set the temperature thresholds in
the Basics:System dialog at the end of the system data.
enable
configure
device-status monitor all en-
able
device-status trap enable

9.2.2 Displaying the device status

Select the Basics:System dialog.
8
9.2 Monitoring the device status
contact").
Switch to the Priviledged EXEC mode.
Switch to the Configuration mode.
Include all the possible events in the device sta-
tus determination.
Enable a trap to be sent if the device status
changes.
(see on page 12
Basic - L3P
Release 4.0 11/07