Identifying A Trip / Trip Source; Trips Associated With Xxyzz Sub-Trip Number; Sub-Trip Identification; Key To Sub-Trip Number - Emerson Powerdrive F300 User Manual

Universal variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for Powerdrive F300:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
13.3

Identifying a trip / trip source

Some trips only contain a trip string whereas some other trips have a trip
string along with a sub-trip number which provides the user with
additional information about the trip.
A trip can be generated from a control system or from a power system.
The sub-trip number associated with the trips listed in Table 13-1 is in
the form xxyzz and used to identify the source of the trip.
Table 13-1 Trips associated with xxyzz sub-trip number
Over Volts
OI ac
PSU
OHt Inverter
OHt Power
OHt Control
The digits xx are 00 for a trip generated by the control system. For a
single drive (not part of a multi-power module drive), if the trip is related
to the power system then xx will have a value of 01, when displayed the
leading zeros are suppressed.
The y digit is used to identify the location of a trip which is generated by
a rectifier module connected to a power module (if xx is non zero). For a
control system trip (xx is zero), the y digit, where relevant is defined for
each trip. If not relevant, the y digit will have a value of zero.
The zz digits give the reason for the trip and are defined in each trip
description.
Figure 13-3 Key to sub-trip number
00 - Generated by the control module
01 - Generated by the power module
0 - Rectifier or thermal model
00
01
- Reason for the trip
.
.
07
For example, if the drive has tripped and the lower line of the display
shows 'OHt Control.2', with the help Table 13-2 below the trip can be
interpreted as; an over temperature has been detected; the trip was
generated by fault in the control module, the control board thermistor 2
over temperature.
Table 13-2 Sub-trip identification
Source
xx
y
zz
Control
00
0
01
Control board thermistor 1 over temperature
system
Control
00
0
02
Control board thermistor 2 over temperature
system
Control
00
0
03
Control board thermistor 3 over temperature
system
Powerdrive F300 User Guide
Issue Number: 2
Electrical
Getting
Basic
installation
started
parameters
the motor
OHt dc bus
Phase Loss
OI Snubber
OHt Rectifier
Temp Feedback
Power Data
x x y z z
Description
Running
NV Media Card
Optimization
Operation
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
data
UL listing
information
261

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents