Emerson Powerdrive F300 User Manual page 204

Universal variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for Powerdrive F300:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Parameter
07.001
Analog Input 1
07.002
Analog Input 2
07.004
Monitored Temperature 1
07.005
Monitored Temperature 2
07.006
Monitored Temperature 3
07.007
Analog Input 1 Mode
07.008
Analog Input 1 Scaling
07.009
Analog Input 1 Invert
07.010
Analog Input 1 Destination
07.011
Analog Input 2 Mode
07.012
Analog Input 2 Scaling
07.013
Analog Input 2 Invert
07.014
Analog Input 2 Destination
07.019
Analog Output 1 Source
07.020
Analog Output 1 Scaling
07.021
Analog Output 1 Mode
07.022
Analog Output 2 Source
07.023
Analog Output 2 Scaling
07.024
Analog Output 2 Mode
07.025
Calibrate Analog Input 1 Full Scale
07.026
Analog Input 1 Fast Update Active
07.027
Analog Input 2 Fast Update Active
07.028
Analog Input 1 Current Loop Loss
07.029
Analog Input 2 Current Loop Loss
07.030
Analog Input 1 Offset
07.031
Analog Input 2 Offset
07.033
Power Output
07.034
Inverter Temperature
07.035
Percentage Of d.c. Bus Thermal Trip Level
07.036
Percentage Of Drive Thermal Trip Level
07.037
Temperature Nearest To Trip Level
07.038
Temperature Monitor Select 1
07.039
Temperature Monitor Select 2
07.040
Analog Input 1 Minimum
07.041
Analog Input 2 Minimum
07.043
Analog Input 1 Maximum
07.044
Analog Input 2 Maximum
07.051
Analog Input 1 Full Scale
07.052
Temperature Monitor Select 3
RW Read / Write
RO
Read only
ND
No default value
NC
Not copied
204
Electrical
Getting
Basic
installation
started
parameters
Range( )
OL
±100.00 %
±100.00 %
4-20 mA Low (-4), 20-4 mA Low (-3), 4-20 mA Hold (-2),
20-4 mA Hold (-1), 0-20 mA (0), 20-0 mA (1),
4-20 mA Trip (2), 20-4 mA Trip (3), 4-20 mA (4),
20-4 mA (5), Volt (6), Therm Short Cct (7), Thermistor (8),
Therm No Trip (9)
0.000 to 10.000
Off (0) or On (1)
0.000 to 59.999
4-20 mA Low (-4), 20-4 mA Low (-3), 4-20 mA Hold (-2),
20-4 mA Hold (-1), 0-20 mA (0), 20-0 mA (1),
4-20 mA Trip (2), 20-4 mA Trip (3), 4-20 mA (4),
20-4 mA (5), Volt (6), Therm Short Cct (7), Thermistor (8),
Therm No Trip (9)
0.000 to 10.000
Off (0) or On (1)
0.000 to 59.999
0.000 to 59.999
0.000 to 10.000
Volt (0), 0-20 mA (1), 20-0 mA (2), 4-20 mA (3), 20-4 mA (4)
0.000 to 59.999
0.000 to 10.000
Volt (0), 0-20 mA (1), 20-0 mA (2), 4-20 mA (3), 20-4 mA (4)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
±100.00 %
±100.00 %
±100.0 %
0 to 100 %
0 to 100 %
0 to 29999
0 to 29999
0 to 29999
±100.00 %
±100.00 %
±100.00 %
±100.00 %
0 to 65535
0 to 29999
Num Number parameter
PT
Protected parameter
Running
NV Media Card
Optimization
the motor
Operation
RFC-A / S
OL
±250 °C
±250 °C
±250 °C
5.001
±250 °C
Bit
Bit parameter
Txt
RA
Rating dependent
US
Onboard
Advanced
Technical
PLC
parameters
data
Default( )
RFC-A
RFC-S
RO
Num
RO
Num
RO
Num
RO
Num
RO
Num
4-20 mA (4)
RW
Txt
1.000
RW
Num
Off (0)
RW
Bit
1.036
RW
Num
Volt (6)
RW
Txt
1.000
RW
Num
Off (0)
RW
Bit
1.037
RW
Num
3.002
RW
Num
1.000
RW
Num
Volt (0)
RW
Txt
4.002
RW
Num
1.000
RW
Num
Volt (0)
RW
Txt
Off (0)
RW
Bit
RO
Bit
RO
Bit
RO
Bit
RO
Bit
0.00 %
RW
Num
0.00 %
RW
Num
RO
Num
RO
Num
RO
Num
RO
Num
RO
Num
1001
RW
Num
1002
RW
Num
-100.00 %
RW
Num
-100.00 %
RW
Num
100.00 %
RW
Num
100.00 %
RW
Num
RO
Num
1
RW
Num
Text string
Bin
Binary parameter
User save
PS
Power-down save
Powerdrive F300 User Guide
UL listing
Diagnostics
information
Type
ND
NC
PT
FI
ND
NC
PT
FI
ND
NC
PT
ND
NC
PT
ND
NC
PT
US
US
US
DE
PT
US
US
US
US
DE
PT
US
PT
US
US
US
US
NC
ND
NC
PT
ND
NC
PT
ND
NC
PT
ND
NC
PT
US
US
ND
NC
PT
ND
NC
PT
ND
NC
PT
ND
NC
PT
ND
NC
PT
US
US
US
US
US
US
ND
NC
PT
PS
US
FI
Filtered
DE
Destination
Issue Number: 2