Safety
Product
Mechanical
information
information
installation
Trip
HF15
Data processing error: CPU divide error
The HF15 trip indicates that a CPU divide error has occurred. This trip indicates that the control PCB on the drive has
failed.
Recommended actions:
Hardware fault – Contact the supplier of the drive
HF16
Data processing error: RTOS error
The HF16 trip indicates that a RTOS error has occurred. This trip indicates that the control PCB on the drive has failed.
Recommended actions:
Hardware fault – Contact the supplier of the drive
HF17
Data processing error: Clock supplied to the control board is out of specification
The HF17 trip indicates that the clock supplied to the control board logic is out of specification. This trip indicates that the
control PCB on the drive has failed.
Recommended actions:
Hardware fault – Contact the supplier of the drive
HF18
Data processing error: Internal flash memory has failed
The HF18 trip indicates that the internal flash memory has failed when writing option module parameter data. The reason
for the trip can be identified by the sub-trip number.
Sub-trip
1
2
3
4
5
6
7
8
9
Recommended actions:
Hardware fault - Contact the supplier of the drive.
HF19
Data processing error: CRC check on the firmware has failed
The HF19 trip indicates that the CRC check on the drive firmware has failed.
Recommended actions:
Re-program the drive
Hardware fault - Contact the supplier of the drive
HF20
Data processing error: ASIC is not compatible with the hardware
The HF20 trip indicates that the ASIC version is not compatible with the drive firmware. The ASIC version can be identified
from the sub-trip number.
Recommended actions:
Hardware fault - Contact the supplier of the drive
I/O Overload
Digital output overload
The I/O Overload trip indicates that the total current drawn from 24 V user supply or from the digital output has exceeded
the limit. A trip is initiated if one or more of the following conditions:
Maximum output current from one digital output is 100 mA.
The combined maximum output current from outputs 1 and 2 is 100 mA
26
The combined maximum output current from output 3 and +24 V output is 100 mA
Recommended actions:
Check total loads on digital outputs
Check control wiring is correct
Check output wiring is undamaged
Keypad Mode
Keypad has been removed when the drive is receiving the speed reference from the keypad
The Keypad Mode trip indicates that the drive is in keypad mode [Reference Selector (01.014) = 4 or 6] and the keypad has
been removed or disconnected from the drive.
34
Recommended actions:
Re-install keypad and reset
Change Reference Selector (01.014) to select the reference from another source
268
Electrical
Getting
Basic
installation
started
parameters
the motor
Option module initialization timed out
Programming error while writing menu in flash
Erase flash block containing setup menus failed
Erase flash block containing application menus failed
Incorrect setup menu CRC contained in flash
Incorrect application menu CRC contained in flash
Incorrect common application menu 18 CRC contained in flash
Incorrect common application menu 19 CRC contained in flash
Incorrect common application menu 20 CRC contained in flash
Running
NV Media Card
Optimization
Operation
Diagnosis
Reason
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
data
Powerdrive F300 User Guide
UL listing
information
Issue Number: 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents