Trip Categories - Emerson Powerdrive F300 User Manual

Universal variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for Powerdrive F300:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
The trips can be grouped into the following categories. It should be noted that a trip can only occur when the drive is not tripped or is already tripped
but with a trip with a lower priority number.
Table 13-5 Trip categories
Priority
Category
1
Internal faults
1
Stored HF trip
2
Non-resettable trips
3
Volatile memory failure
Internal 24 V power
3
supply
4
NV Media Card trips
Trips with extended reset
5
times
Phase loss and d.c. link
5
power circuit protection
5
Standard trips
Powerdrive F300 User Guide
Issue Number: 2
Electrical
Getting
Basic
installation
started
parameters
the motor
Trips
HF01, HF02, HF03, HF04,
HF05, HF06, HF07, HF08,
HF09, HF10, HF11, HF12,
HF13, HF14, HF15, HF16,
HF17, HF18, HF19, HF20
{Stored HF}
Trip numbers 218 to 247,
{Slot1 HF}, {Slot2 HF},
{Slot3 HF} or {Slot4 HF}
{EEPROM Fail}
{PSU 24}
Trip numbers 174, 175
and 177 to 188
{OI ac} and OI dc}
{Phase Loss} and
{Oht dc bus}
All other trips
Running
NV Media Card
Optimization
Operation
These indicate internal problems and cannot be reset. All drive features
are inactive after any of these trips occur. If a KI-Keypad is installed it will
show the trip, but the keypad will not function.
This trip cannot be cleared unless 1299 is entered into Parameter
(mm.000) and a reset is initiated.
These trips cannot be reset.
This can only be reset if Parameter mm.000 is set to 1233 or 1244, or if
Load Defaults (11.043) is set to a non-zero value.
These trips are priority 5 during power-up.
These trips cannot be reset until 10 s after the trip was initiated.
The drive will attempt to stop the motor before tripping if a {Phase Loss}.
000 trip occurs unless this feature has been disabled (see Action On Trip
Detection (10.037). The drive will always attempt to stop the motor before
tripping if an {Oht dc bus} occurs.
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
data
Comments
UL listing
information
281