24 Vdc Supply; Dc Bus Paralleling Kit Part Numbers; 24 Vdc Supply Connections; Location Of The 24 Vdc Power Supply Connection On Size 6 - Emerson Powerdrive F300 User Manual

Universal variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for Powerdrive F300:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
NOTE
The DC bus paralleling kit is not supplied with the drive but available to
order.
Table 4-4 DC bus paralleling kit part numbers
Size
3
4
5
6
4.5

24 Vdc supply

The 24 Vdc supply connected to control terminals 1 & 2 provides the
following functions:
It can be used to supplement the drive's own internal 24 V supply
when multiple option modules are being used and the current drawn
by these module is greater than the drive can supply.
It can be used as a back-up power supply to keep the control circuits
of the drive powered up when the line power supply is removed. This
allows any fieldbus modules, application modules, or serial
communications to continue to operate.
It can be used to commission the drive when the line power supply is
not available, as the display operates correctly. However, the drive
will be in the Under voltage trip state unless either line power supply
or low voltage DC operation is enabled, therefore diagnostics may
not be possible. (Power down save parameters are not saved when
using the 24 V back-up power supply input).
If the DC bus voltage is too low to run the main SMPS in the drive,
then the 24 V supply can be used to supply all the low voltage power
requirements of the drive. Low Under Voltage Threshold Select
(06.067) must also be enabled for this to happen.
NOTE
On size 6 and larger, the power 24 Vdc supply (terminals 51, 52) must
be connected to enable the 24 Vdc supply to be used as a backup
supply, when the line power supply is removed. If the power 24 Vdc
supply is not connected none of the above mentioned functions can be
used, "Waiting For Power Systems" will be displayed on the keypad and
no drive operations are possible. The location of the power 24 Vdc can
be identified from Figure 4-17 Location of the 24 Vdc power supply
connection on size 6 on page 80.
Table 4-5 24 Vdc Supply connections
Function
Supplement the drive's
internal supply
Back-up supply for the
control circuit
The working voltage range of the control 24 V power supply is as
follows:
1
0 V
2
+24 Vdc
Nominal operating voltage
Minimum continuous operating voltage
Maximum continuous operating voltage
Minimum start up voltage
Maximum power supply requirement at 24 V
Recommended fuse
Minimum and maximum voltage values include ripple and noise. Ripple
and noise values must not exceed 5 %.
80
Electrical
Getting
Basic
installation
started
parameters
CT part number
3470-0048-00
3470-0061-00
3470-0068-00
3470-0063-00
Sizes 3-5
Sizes 6-11
Terminal
Terminal
1, 2
1, 2
Terminal
Terminal
1, 2
1, 2
51, 52
24.0 Vdc
19.2 V
28.0 V
21.6 V
40 W
3 A, 50 Vdc
Running
NV Media Card
Optimization
the motor
Operation
The working range of the 24 V power supply is as follows:
51
0 V
52
+24 Vdc
Size 6
Nominal operating voltage
Minimum continuous operating voltage
Maximum continuous operating voltage
Minimum startup voltage
Maximum power supply requirement
Recommended fuse
Size 7 to 11
Nominal operating voltage
Minimum continuous operating voltage
Maximum continuous operating voltage
Minimum startup voltage
Maximum power supply requirement
Recommended fuse
Figure 4-17 Location of the 24 Vdc power supply connection on size 6
1. 24 Vdc power supply connection
Figure 4-18 Location of the 24 Vdc power supply connection on size 7
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
data
24.0 Vdc
18.6 Vdc
28.0 Vdc
18.4 Vdc
40 W
4 A @ 50 Vdc
24.0 Vdc
19.2 Vdc
30 Vdc (IEC),
26 Vdc (UL)
21.6 Vdc
60 W
4 A @ 50 Vdc