Parameter ranges and Variable minimum/maximums:

Some parameters in the drive have a variable range with a variable minimum and a variable maximum values which is dependent on one of the
following:
The settings of other parameters
The drive rating
The drive mode
Combination of any of the above
The tables below give the definition of variable minimum/maximum and the maximum range of these.
VM_AC_VOLTAGE
Units
V
Range of [MIN]
0
Range of [MAX]
0 to the value listed below
VM_AC_VOLTAGE[MAX] is drive voltage rating dependent. See Table 11-4
Definition
VM_AC_VOLTAGE[MIN] = 0
VM_AC_VOLTAGE_SET
Units
V
Range of [MIN]
0
Range of [MAX]
0 to the value listed below
VM_AC_VOLTAGE[MAX] is drive voltage rating dependent. See Table 11-4
Definition
VM_AC_VOLTAGE[MIN] = 0
VM_ACCEL_RATE
Units
s / 100 Hz, s / 1000 rpm, s / 1000 mm/s
Open-loop: 0.0
Range of [MIN]
RFC-A, RFC-S: 0.000
Open-loop: 0.0 to 3200.0
Range of [MAX]
RFC-A, RFC-S: 0.000 to 3200.000
Open-loop mode
If Ramp Rate Units (02.039) = 0:
VM_ACCEL_RATE[MAX] = 3200.0
If Ramp Rate Units (02.039) = 1:
VM_ACCEL_RATE[MAX] = 3200.0 x Pr 01.006 / 100.0
VM_ACCEL_RATE[MIN] = 0.0
Definition
RFC-A, RFC-S modes
If Ramp Rate Units (02.039) = 0:
VM_ACCEL_RATE[MAX] = 3200.000
If Ramp Rate Units (02.039) = 1:
VM_ACCEL_RATE[MAX] = 3200.000 x Pr 01.006 / 1000.0
VM_ACCEL_RATE[MIN] = 0.000
If the second motor map is selected (Pr 11.045 = 1) Pr 21.001 is used instead of Pr 01.006.
VM_AMC_ROLL_OVER
Units
User units
Range of [MIN]
0 or -2
Range of [MAX]
0 or -2
VM_AMC_ROLL_OVER[MAX] = 2
Definition
VM_AMC_ROLL_OVER[MIN] = 2
172
Electrical
Getting
Basic
installation
started
parameters
Range applied to parameters showing AC voltage
Range applied to the AC voltage set-up parameters
Maximum applied to the ramp rate parameters
Range applied the position parameters in the advanced motion controller
31
31
-1
31
Running
NV Media Card
Optimization
the motor
Operation
31
-1
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
data
Powerdrive F300 User Guide
UL listing
information
Issue Number: 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents