Dyneo Lsrpm 2400/3000 Rpm Motors - Emerson Powerdrive F300 User Manual

Universal variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for Powerdrive F300:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Table 7-5 Dyneo LSRPM 2400 rpm motors
LSRPM Motor model
2400 LSRPM 90SL 4.8 kW
2400 LSRPM 100L 7.2 kW
2400 LSRPM 100L 9.5 kW
2400 LSRPM 132M 13.1 kW
2400 LSRPM 132M 16.3 kW
2400 LSRPM 132M 19.2 kW
2400 LSRPM 160MP 25 kW
2400 LSRPM 160MP 31 kW
2400 LSRPM 160LR 36 kW
2400 LSRPM 200L 50 kW
2400 LSRPM 200L1 65 kW
2400 LSRPM 200L1 80 kW
2400 LSRPM 225MR1 100 kW
2400 LSRPM 250SE 125 kW
2400 LSRPM 250ME 150 kW
2400 LSRPM 280SD1 190 kW
2400 LSRPM 280MK1 230 kW
* From firmware version 01.12.xx.xx onwards, the rated current from the motor nameplate is entered into Pr 05.007 / Pr 00.046 and will be updated
automatically to the sensorless value after an autotune.
Table 7-6 Dyneo LSRPM 3000 rpm motors
LSRPM Motor model
3000 LSRPM 90SL 5.8 kW
3000 LSRPM 100L 8.7 kW
3000 LSRPM 100L 11.6 kW
3000 LSRPM 132M 15.8 kW
3000 LSRPM 132M 19.7 kW
3000 LSRPM 132M 23 kW
3000 LSRPM 160MP 30 kW
3000 LSRPM 160MP 37 kW
3000 LSRPM 160LR 44 kW
3000 LSRPM 200L 50 kW
3000 LSRPM 200L1 65 kW
3000 LSRPM 200L1 85 kW
3000 LSRPM 225ST2 110 kW
3000 LSRPM 250SE 145 kW
3000 LSRPM 250ME1 170 kW
3000 LSRPM 280SD1 200 kW
3000 LSRPM 280SD1 220 kW
* From firmware version 01.12.xx.xx onwards, the rated current from the motor nameplate is entered into Pr 05.007 / Pr 00.046 and will be updated
automatically to the sensorless value after an autotune.
144
Electrical
Getting
Basic
installation
started
parameters
the motor
Motor rated current
(nameplate value)
*
Pr 00.046
A
9.1
13.4
17.7
25.0
31.0
37.0
47.0
58.0
69.0
110
137
160
200
235
285
350
429
Motor rated current
(nameplate value)
*
Pr 00.046
A
11.0
16.2
21.0
30.0
38.0
44.0
57.0
67.8
82.0
111
126
170
215
285
338
365
370
Running
NV Media Card
Optimization
Operation
Sensorless motor
Switching
rated current after
frequency
*
Pr 00.041
autotune
A
9.4
13.4
17.7
27.2
32.1
37.1
47.0
58.0
69.0
110
137
164
201
240
288
361
429
Sensorless motor
Switching
rated current after
frequency
*
autotune
Pr 00.041
A
11.1
16.2
21.0
31.8
38.0
44.0
57.0
67.8
82.0
116
136
170
219
285
344
365
398
Onboard
Advanced
Technical
PLC
parameters
data
Ke
Pr 00.047
kHz
V/1000 rpm
4
145
4
146
4
151
8
149
8
140
8
152
8
153
8
156
8
156
4
136
4
128
4
145
4
142
4
146
4
146
4
152
4
147
Ke
Pr 00.047
kHz
V/1000 rpm
4
120
4
131
4
134
8
121
8
121
8
126
8
127
8
128
8
129
4
109
4
118
4
125
4
118
4
114
4
111
4
126
4
130
Powerdrive F300 User Guide
UL listing
Diagnostics
information
Motor Thermal
Time Constant
Pr 00.053
s
850
850
850
1050
1050
1050
1050
1050
1050
900
900
900
900
1150
1150
1150
2600
Motor Thermal
Time Constant
Pr 00.053
s
850
850
850
1050
1050
1050
1050
1050
1050
900
900
900
900
1150
1150
1150
1150
Issue Number: 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents