Safety
Product
Mechanical
information
information
installation
VM_AMC_UNIPOLAR_ROLL_OVER
Units
User units
Range of [MIN]
0 L
Range of [MAX]
0 to 2
VM_AMC_UNIPOLAR_ROLL_OVER[MAX] = VM_AMC_ROLL_OVER[MAX]
Definition
VM_AMC_UNIPOLAR_ROLL_OVER[MIN] = 0
VM_DC_VOLTAGE
Units
V
Range of [MIN]
0
Range of [MAX]
0 to the value listed below
VM_DC_VOLTAGE[MAX] is the full scale d.c. link voltage feedback (over voltage trip level) for the drive. This level is
drive voltage rating dependent. See Table 11-4
Definition
VM_DC_VOLTAGE[MIN] = 0
VM_DC_VOLTAGE_SET
Units
V
Range of [MIN]
0
Range of [MAX]
0 to the value listed below
VM_DC_VOLTAGE_SET[MAX] is drive voltage rating dependent. See Table 11-4
Definition
VM_DC_VOLTAGE_SET[MIN] = 0
VM_DRIVE_CURRENT
Units
A
Range of [MIN]
-99999.999 to 0.000
Range of [MAX]
0.000 to 99999.999
VM_DRIVE_CURRENT[MAX] is equivalent to the full scale (over current trip level) or Kc value for the drive and is given
by Full Scale Current Kc (11.061).
Definition
VM_DRIVE_CURRENT[MIN] = - VM_DRIVE_CURRENT[MAX]
VM_DRIVE_CURRENT_UNIPOLAR
Units
A
Range of [MIN]
0.000
Range of [MAX]
0.000 to 99999.999
VM_DRIVE_CURRENT_UNIPOLAR[MAX] = VM_DRIVE_CURRENT[MAX]
Definition
VM_DRIVE_CURRENT_UNIPOLAR[MIN] = 0.000
Powerdrive F300 User Guide
Issue Number: 2
Electrical
Getting
Basic
installation
started
parameters
the motor
Range applied the position parameters in the advanced motion controller that are restricted
to positive values
31
-1
Range applied to parameters showing DC voltage
Range applied to DC voltage reference parameters
Range applied to parameters showing current in A
Unipolar version of VM_DRIVE_CURRENT