Table 6-2 Functions in Pr mm.000
Value
Save parameters when Under Voltage Active (Pr 10.016) is not active and Low Under Voltage Threshold Select mode (Pr 06.067 = Off)
1000
is not active.
1001
Save parameter under all conditions
1070
Reset all option modules
1233
Load standard (50 Hz) defaults
1234
Load standard (50 Hz) defaults to all menus except option module menus (i.e 15 to 20 and 24 to 28)
1244
Load US (60 Hz) defaults
1245
Load US (60 Hz) defaults to all menus except option module menus (i.e 15 to 20 and 24 to 28)
1253
Change drive mode and load standard (50 Hz) defaults
1254
Change drive mode and load US (60 Hz) defaults
1255
Change drive mode and load standard (50 Hz) defaults except for menus 15 to 20 and 24 to 28
1256
Change drive mode and load US (60 Hz) defaults except for menus 15 to 20 and 24 to 28
1299
Reset {Stored HF} trip.
2001*
Create a boot file on a non-volatile media card based on the present drive parameters including all Menu 20 parameters
4yyy*
NV media card: Transfer the drive parameters to parameter file xxx
5yyy*
NV media card: Transfer the onboard user program to onboard user program file xxx
6yyy*
NV media card: Load the drive parameters from parameter file xxx or the onboard user program from onboard user program file xxx
7yyy*
NV media card: Erase file xxx
8yyy*
NV Media card: Compare the data in the drive with file xxx
9555*
NV media card: Clear the warning suppression flag
9666*
NV media card: Set the warning suppression flag
9777*
NV media card: Clear the read-only flag
9888*
NV media card: Set the read-only flag
9999*
NV media card: Erase and format the NV media card
12000**
Only display parameters that are different from their default value. This action does not require a drive reset.
12001**
Only display parameters that are used to set-up destinations (i.e. DE format bit is 1). This action does not require a drive reset.
40yyy
Back-up all drive data.
60yyy
Load all drive data.
* See Chapter 9 NV Media Card Operation on page 162 for more information on these functions.
** These functions do not require a drive reset to become active. All other functions require a drive reset to initiate the function.
To allow easy access to some commonly used functions, refer to the table overleaf. Equivalent values and strings are also provided in the table
above.
Powerdrive F300 User Guide
Issue Number: 2
Electrical
Getting
Basic
installation
started
parameters
the motor
Running
NV Media Card
Optimization
Operation
Action
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
data
UL listing
information
117

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents