Maximum Motor Cable Lengths (200/400 V Drives) - Emerson Powerdrive F300 User Manual

Universal variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for Powerdrive F300:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
12.1.24
Maximum motor cable lengths
Table 12-25 Maximum motor cable lengths (200 V drives)
Model
03200066
03200080
03200110
03200127
04200180
04200250
05200300
06200500
300 m
(984 ft)
06200580
07200750
07200940
07201170
08201490
08201800
09202160
09202660
10203250
10203600
Table 12-26 Maximum motor cable lengths (400 V drives)
Model
03400034
03400045
03400062
03400077
03400104
03400123
04400185
04400240
05400300
06400380
06400480
06400630
07400790
07400940
07401120
08401550
08401840
09402210
09402660
10403200
10403610
11404370
11404870
11405070
Powerdrive F300 User Guide
Issue Number: 2
Electrical
Getting
Basic
installation
started
parameters
200 V Nominal AC supply voltage
Maximum permissible motor cable length for each of the following switching frequencies
2
3
kHz
kHz
100 m (330 ft)
130 m (425 ft)
200 m (660 ft)
200 m (660 ft)
200 m (660 ft)
200 m
(660 ft)
250 m (820 ft)
250 m (820 ft)
250 m (820 ft)
250 m (820 ft)
400 V Nominal AC supply voltage
Maximum permissible motor cable length for each of the following switching frequencies
2
3
kHz
kHz
100 m (330 ft)
130 m (425 ft)
200 m (660 ft)
200 m (660 ft)
200 m (660 ft)
300 m
200 m
(984 ft)
(660 ft)
250 m (820 ft)
250 m (820 ft)
250 m (820 ft)
250 m (820 ft)
250 m (820 ft)
Running
NV Media Card
Optimization
the motor
Operation
4
6
kHz
kHz
65 m (210 ft)
100 m
(330 ft)
150 m (490 ft)
150 m
100 m
(490 ft)
(330 ft)
150 m
100 m
(490 ft)
(330 ft)
150 m
100 m
(490 ft)
(330 ft)
185 m
125 m
(607 ft)
(410 ft)
185 m
125 m
(607 ft)
(410 ft)
4
6
kHz
kHz
65 m (210 ft)
100 m
150 m
(330 ft)
(490 ft)
150 m
100 m
(490 ft)
(330 ft)
150 m
100 m
(490 ft)
(330 ft)
150 m
100 m
(490 ft)
(330 ft)
185 m
125 m
(607 ft)
(410 ft)
185 m
125 m
(607 ft)
(410 ft)
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
data
8
12 kHz
kHz
50 m
75 m
(165 ft)
(245 ft)
75 m
50 m
(245 ft)
(165 ft)
75 m
50 m
(245 ft)
(165 ft)
75 m
50 m
(245 ft)
(165 ft)
90 m
(295 ft)
90 m
(295 ft)
8
12
kHz
kHz
50 m
75 m
(165 ft)
(245 ft)
75 m
50 m
(245 ft)
(165 ft)
75 m
50 m
(245 ft)
(165 ft)
75 m
50 m
(245 ft)
(165 ft)
90 m
(295 ft)
90 m
(295 ft)
UL listing
information
16 kHz
37 m
(120 ft)
37 m
(120 ft)
37 m
(120 ft)
16
kHz
37 m
(120 ft)
37 m
(120 ft)
37 m
(120 ft)
251

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents