Table 12-48 Size 8 emission compliance (400 V drives)
Switching Frequency (kHz)
Motor cable
length (m)
2
3
Using internal filter:
2 – 10
No advantage to using ferrite ring
Using external filter:
0 – 20
R(C1)
I(C2)
20 – 50
R(C1)
R(C1)
50 – 100
I(C2)
I(C2)
Table 12-49 Size 8 emission compliance (575 V and 690 V drives)
Switching Frequency (kHz)
Motor cable
length (m)
2
3
Using internal filter:
2 – 10
No advantage to using ferrite ring
Using external filter:
0 – 20
R(C1)
I(C2)
20 – 50
R(C1)
R(C1)
50 – 100
R(C1)
R(C1)
Table 12-50 Size 9E and 10E emission compliance (200 V drives)
Switching Frequency (kHz)
Motor cable
length (m)
2
Using internal filter:
2 – 10
No advantage to using ferrite ring
Using external filter:
0 – 20
R(C1)
I(C2)
20 – 100
I(C2)
I(C2)
Table 12-51 Size 9E and 10E emission compliance (400 V drives)
Switching Frequency (kHz)
Motor cable
length (m)
2
Using internal filter:
2 – 10
No advantage to using ferrite ring
Using external filter:
0 – 20
R(C1)
I(C2)
20 – 100
I(C2)
I(C2)
Table 12-52 Size 9E and 10E emission compliance (575 V and
690 V drives)
Switching Frequency (kHz)
Motor cable
length (m)
2
Using internal filter:
2 – 10
No advantage to using ferrite ring
Using external filter:
0 – 20
R(C1)
I(C2)
20 – 100
I(C2)
I(C2)
Key (shown in decreasing order of permitted emission level):
E2R
EN 61800-3:2004 second environment, restricted distribution
(Additional measures may be required to prevent interference)
E2U
EN 61800-3:2004 second environment, unrestricted distribution
I
Industrial generic standard EN 61000-6-4:2007
Powerdrive F300 User Guide
Issue Number: 2
Electrical
Getting
Basic
installation
started
parameters
4
6
8
12
C3
I(C2)
I(C2)
I(C2)
I(C2)
R(C1)
I(C2)
I(C2)
I(C2)
I(C2)
4
6
8
12
C4
I(C2)
I(C2)
I(C2)
I(C2)
I(C2)
I(C2)
I(C2)
I(C2)
R(C1)
I(C2)
I(C2)
I(C2)
3
4
6
8
C3
I(C2)
I(C2)
I(C2)
3
4
6
8
C3
I(C2)
I(C2)
I(C2)
3
4
6
8
C3
I(C2)
I(C2)
I(C2)
Running
NV Media Card
Optimization
the motor
Operation
EN 61800-3:2004 first environment restricted distribution (The
following caution is required by EN 61800-3:2004)
This is a product of the restricted distribution class according
16
to IEC 61800-3. In a residential environment this product may
cause radio interference in which case the user may be
required to take adequate measures.
CAUTION
R
Residential generic standard EN 61000-6-3:2007
I(C2)
EN 61800-3:2004 first environment unrestricted distribution
I(C2)
EN 61800-3:2004 defines the following:
The first environment is one that includes residential premises. It
also includes establishments directly connected without intermediate
transformers to a low-voltage power supply network which supplies
buildings used for residential purposes.
The second environment is one that includes all establishments
16
other than those directly connected to a low-voltage power supply
network which supplies buildings used for residential purposes.
Restricted distribution is defined as a mode of sales distribution in
which the manufacturer restricts the supply of equipment to
suppliers, customers or users who separately or jointly have
I(C2)
technical competence in the EMC requirements of the application of
drives.
I(C2)
I(C2)
IEC 61800-3:2004 and EN 61800-3:2004
The 2004 revision of the standard uses different terminology to align the
requirements of the standard better with the EC EMC Directive.
Power drive systems are categorized C1 to C4:
12
Category
Intended for use in the first or second
C1
environments
I(C2)
Not a plug-in or movable device, and
intended for use in the first environment
C2
only when installed by a professional, or
in the second environment
Intended for use in the second
C3
environment, not the first environment
12
Rated at over 1000 V or over 400 A ,
C4
intended for use in complex systems in
the second environment
Note that category 4 is more restrictive than E2R, since the rated current
of the PDS must exceed 400 A or the supply voltage exceed 1000 V, for
I(C2)
the complete PDS.
12
I(C2)
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
data
Definition
UL listing
information
Corresponding
code used
above
R
I
E2U
E2R