Safety
Product
Mechanical
information
information
installation
5.8

Restoring parameter defaults

Restoring parameter defaults by this method saves the default values in
the drives memory. User security status (00.049) and User security code
(00.034) are not affected by this procedure).
Procedure
1. Ensure the drive is not enabled, i.e. terminal 29 is open or Pr 06.015
is OFF (0)
2. Select 'Reset 50 Hz Defs' or 'Reset 60 Hz Defs' in Pr mm.000.
(alternatively, enter 1233 (50 Hz settings) or 1244 (60 Hz settings) in
Pr mm.000).
3. Either:
Press the red
reset button
Toggle the reset digital input
Carry out a drive reset through serial communications by setting
Pr 10.038 to 100
5.9

Parameter access level and security

The parameter access level determines whether the user has access to
Menu 0 only or to all the advanced menus (Menus 1 to 41) in addition to
Menu 0.
The User Security determines whether the access to the user is read
only or read write.
Both the User Security and Parameter Access Level can operate
independently of each other as shown in Table 5-10.
Table 5-10 Parameter access level and security
User
security
Access level
status
(11.044)
Open
0
Menu 0
Closed
Open
1
All Menus
Closed
Open
Read-only
2
Menu 0
Closed
Open
3
Read-only
Closed
Open
4
Status only
Closed
Open
5
No access
Closed
The default settings of the drive are Parameter Access Level Menu 0
and user Security Open i.e. read / write access to Menu 0 with the
advanced menus not visible.
Powerdrive F300 User Guide
Issue Number: 2
Electrical
Getting
Basic
installation
started
parameters
User
Menu 0
Advanced
security
status
menu status
RW
Not visible
RO
Not visible
RW
RW
RO
RO
RO
Not visible
RO
Not visible
RO
RO
RO
RO
Not visible
Not visible
Not visible
Not visible
Not visible
Not visible
Not visible
Not visible
Running
NV Media Card
Optimization
the motor
Operation
5.9.1

User Security Level / Access Level

The drive provides a number of different levels of security that can be set
by the user via User Security Status (11.044); these are shown in the
table below.
User Security
Status
(Pr 11.044)
Menu 0 (0)
All menus (1)
Read- only
Menu 0 (2)
Read-only (3)
Status only (4)
No access (5)
5.9.2
Changing the User Security Level /Access
Level
The security level is determined by the setting of Pr 00.049 or Pr 11.044.
The Security Level can be changed through the keypad even if the User
Security Code has been set.
5.9.3

User Security Code

The User Security Code, when set, prevents write access to any of the
parameters in any menu.
Setting User Security Code
Enter a value between 1 and 2147483647 in Pr 00.034 and press the
button; the security code has now been set to this value. In order
to activate the security, the Security level must be set to desired level in
Pr 00.049. When the drive is reset, the security code will have been
activated and the drive returns to Menu 0 and the
displayed in the right hand corner of the keypad display. The value of
Pr 00.034 will return to 0 in order to hide the security code.
Unlocking User Security Code
Select a parameter that need to be edited and press the
the upper display will now show 'Security Code'. Use the arrow buttons
to set the security code and press the
security code entered, the display will revert to the parameter selected in
edit mode.
If an incorrect security code is entered, the following message 'Incorrect
security code' is displayed, then the display will revert to parameter view
mode.
Disabling User Security
Unlock the previously set security code as detailed above. Set Pr 00.034
to 0 and press the
disabled, and will not have to be unlocked each time the drive is
powered up to allow read / write access to the parameters.
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
data
Description
All writable parameters are available to be edited
but only parameters in Menu 0 are visible
All parameters are visible and all writable
parameters are available to be edited
Access is limited to Menu 0 parameters only. All
parameters are read-only
All parameters are read-only however all menus
and parameters are visible
The keypad remains in status mode and no
parameters can be viewed or edited
The keypad remains in status mode and no
parameters can be viewed or edited. Drive
parameters cannot be accessed via a comms/
fieldbus interface in the drive or any option module
button. With the correct
button. The User Security has now been
UL listing
information
symbol is
button,