Acoustic Noise; Overall Dimensions; Weights; Safe Torque Off Data - Emerson Powerdrive F300 User Manual

Universal variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for Powerdrive F300:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
12.1.17

Acoustic noise

The heatsink fan generates the majority of the sound pressure level at 1 m
produced by the drive. The heatsink fan on all drive sizes are a variable
speed
fan.
The drive controls the speed at which the fan runs based on
the temperature of the heatsink and the drive's thermal model system.
Table 12-10 gives the sound pressure level at 1 m produced by the drive
for the heatsink fan running at the maximum and minimum speeds.
Table 12-10 Acoustic noise data
Max speed
Size
3
4
5
6
7
8
9
10
11
12.1.18

Overall dimensions

H
Height including surface mounting brackets
W
Width
D
Projection forward of panel when surface mounted
F
Projection forward of panel when through-panel mounted
R
Projection rear of panel when through-panel mounted
Table 12-11 Overall drive dimensions
Size
H
W
382 mm
83 mm
3
(15.04 in)
(3.27 in)
391 mm
124 mm
4
(15.39 in)
(4.88 in)
391 mm
143 mm
5
(15.39 in)
(5.63 in)
391 mm
210 mm
6
(15.39 in)
(8.27 in)
557 mm
270 mm
7
(21.93 in)
(10.63 in)
803 mm
310 mm
8
(31.61 in)
(12.21 in)
1108 mm
310 mm
9A
(43.61 in)
(12.21 in)
9E and
1069 mm
310 mm
10E
(42.09 in)
(12.21 in)
1242 mm
310 mm
11E
(48.9 in)
(12.21 in)
244
Electrical
Getting
Basic
installation
started
parameters
Min speed
dBA
dBA
56
20
58
35
61
25
58
47
65
52
68
51
75
56
77
55
TBC
TBC
Dimension
D
F
67 mm
(2.64 in)
200 mm
134 mm
(7.87 in)
(5.28 in)
66 mm
(2.59 in)
202 mm
135 mm
67 mm
(7.95 in)
(5.32 in)
(2.64 in)
227 mm
131 mm
96 mm
(8.94 in)
(5.16 in)
(3.78 in)
279 mm
187 mm
92 mm
(10.98 in)
(7.36 in)
(3.62 in)
290 mm
190 mm
100 mm
(11.42 in)
(7.48 in)
(3.94 in)
290 mm
190 mm
100 mm
(11.42 in)
(7.48 in)
(3.94 in)
289 mm
190 mm
99 mm
(11.38 in)
(7.48 in)
(3.90 in)
312 mm
190 mm
122 mm
(12.28 in)
(7.48 in)
(4.8 in)
Running
NV Media Card
Optimization
the motor
Operation
12.1.19

Weights

Table 12-12 Overall drive weights
Size
3
4
5
6
7
8
9A
9E/10E
11E
12.1.20

Safe Torque Off data

Data as verified by TÜV Rheinland:
According to EN ISO 13849-1:
PL = e
Category = 4
MTTF
= High
D
DC
= High
av
Mission Time and Proof Test Interval = 20 years
The calculated MTTF
STO1 2574 yr
According to EN 61800-5-2:
R
SIL = 3
-11
PFH = 4.21 x 10
Logic levels comply with IEC 61131-2:2007 for type 1 digital inputs rated
at 24 V. Maximum level for logic low to achieve SIL3 and PL e 5 V and
0.5 mA.
12.1.21
Input current, fuse and cable size ratings
The input current is affected by the supply voltage and impedance.
Typical input current
The values of typical input current are given to aid calculations for power
flow and power loss.
The values of typical input current are stated for a balanced supply.
Maximum continuous input current
The values of maximum continuous input current are given to aid the
selection of cables and fuses. These values are stated for the worst case
condition with the unusual combination of stiff supply with bad balance.
The value stated for the maximum continuous input current would only
be seen in one of the input phases. The current in the other two phases
would be significantly lower.
The values of maximum input current are stated for a supply with a 2 %
negative phase-sequence imbalance and rated at the maximum supply
fault current given in Table 12-13.
Table 12-13 Supply fault current used to calculate maximum input currents
Model
All
Onboard
Advanced
Technical
PLC
parameters
data
Model
03400104, 03400123
All other variants
All variants
66.5
for the complete STO function is:
D
-1
h
Symmetrical fault level (kA)
Powerdrive F300 User Guide
UL listing
Diagnostics
information
kg
lb
4.5
9.9
4.0
8.8
6.5
14.30
7.4
16.30
14
30.90
28
61.70
52
114.64
146.6
46
101.40
63
138.9
100
Issue Number: 2

Hide quick links:

Advertisement

Table of Contents
loading