Advanced Parameters; Menu Descriptions; Powerdrive F300 User Guide Issue Number - Emerson Powerdrive F300 User Manual

Universal variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for Powerdrive F300:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
11

Advanced parameters

This is a quick reference to all parameters in the drive showing units,
ranges limits etc, with block diagrams to illustrate their function. Full
descriptions of the parameters can be found in the Parameter Reference
Guide.
These advanced parameters are listed for reference
purposes only. The lists in this chapter do not include
sufficient information for adjusting these parameters.
Incorrect adjustment can affect the safety of the system,
WARNING
and damage the drive and or external equipment. Before
attempting to adjust any of these parameters, refer to
the Parameter Reference Guide.
Table 11-1 Menu descriptions
Menu
Commonly used basic set up parameters for quick / easy
0
programming
1
Frequency / Speed reference
2
Ramps
3
Frequency slaving, speed feedback and speed control
4
Torque and current control
5
Motor control
6
Sequencer and clock
7
Analog I/O, Temperature monitoring
8
Digital I/O
Programmable logic, motorized pot, binary sum, timers and
9
scope
10
Status and trips
11
Drive set-up and identification, serial communications
12
Threshold detectors and variable selectors
13
Standard motion control
14
User PID controller
15
Option module slot 1 set-up menu
16
Option module slot 2 set-up menu
17
Option module slot 3 set-up menu
18
General option module application menu 1
19
General option module application menu 2
20
General option module application menu 3
22
Menu 0 set-up
23
Not allocated
28
Reserved menu
29
Reserved for pumping functions
30
Onboard user programming application menu
Slot 1
Slot 1 option menus*
Slot 2
Slot 2 option menus*
Slot 3
Slot 3 option menus*
* Only displayed when the option modules are installed.
Powerdrive F300 User Guide
Issue Number: 2
Electrical
Getting
Basic
installation
started
parameters
the motor
Description
Running
NV Media Card
Optimization
Operation
Operation mode abbreviations:
Open-loop:
Sensorless control for induction motors
RFC-A Sensorless:
Asynchronous Rotor Flux Sensorless Control for induction motors
RFC-S Sensorless: Synchronous Rotor Flux Sensorless Control for
synchronous motors including permanent magnet motors.
Default abbreviations:
Standard default value (50 Hz AC supply frequency)
USA default value (60 Hz AC supply frequency)
NOTE
Parameter numbers shown in brackets {...} are the equivalent Menu 0
parameters. Some Menu 0 parameters appear twice since their function
depends on the operating mode.
The Range - RFC-A / S column applies to both RFC-A and RFC-S. For
some parameters, this column applies to only one of these modes, this is
indicated accordingly in the Default columns.
In some cases, the function or range of a parameter is affected by the
setting of another parameter. The information in the lists relates to the
default condition of any parameters affected in this way.
Table 11-2 Key to parameter table coding
Coding
RW
Read/Write: can be written by the user
RO
Read only: can only be read by the user
Bit
1 bit parameter. 'On' or 'Off' on the display
Num
Number: can be uni-polar or bi-polar
Txt
Text: the parameter uses text strings instead of numbers.
Bin
Binary parameter
IP
IP Address parameter
Mac
Mac Address parameter
Date
Date parameter
Time
Time parameter
Chr
Character parameter
Filtered: some parameters which can have rapidly changing
FI
values are filtered when displayed on the drive keypad for
easy viewing.
Destination: This parameter selects the destination of an
DE
input or logic function.
Rating dependent: this parameter is likely to have different
values and ranges with drives of different voltage and
current ratings. Parameters with this attribute will be
transferred to the destination drive by non-volatile storage
RA
media when the rating of the destination drive is different
from the source drive and the file is a parameter file.
However, the values will be transferred if only the current
rating is different and the file is a difference from default
type file.
No default: The parameter is not modified when defaults are
ND
loaded
Not copied: not transferred to or from non-volatile media
NC
during copying.
PT
Protected: cannot be used as a destination.
User save: parameter saved in drive EEPROM when the
US
user initiates a parameter save.
Power-down save: parameter automatically saved in drive
PS
EEPROM when the under volts (UV) trip occurs.
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
data
Attribute
UL listing
information
169

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents