Tools Required to Install the MX240 Router without a Mechanical Lift

Related
Documentation
Removing Components from the MX240 Router Before Installing it without a Lift
Removing the Power Supplies Before Installing the MX240 Router without a Lift
Copyright © 2016, Juniper Networks, Inc.
Tools Required to Install the MX240 Router with a Mechanical Lift on page 170
Removing Components from the MX240 Router Before Installing it with a Lift on page 170
Installing the MX240 Router By Using a Mechanical Lift on page 175
Preventing Electrostatic Discharge Damage to an MX240 Router on page 416
To install the router, you need the following tools and parts:
Phillips (+) screwdrivers, numbers 1 and 2
7/16-in. nut driver
ESD grounding wrist strap
Removing Components from the MX240 Router Before Installing it without a Lift on
page 181
Installing the MX240 Chassis in the Rack Manually on page 186
Reinstalling Components in the MX240 Router After Installing it without a Lift on
page 188
To make the router light enough to install manually, you first remove most components
from the chassis. The procedures in this section for removing components from the
chassis are for initial installation only, and assume that you have not connected power
cables to the router. The following procedures describe how to remove components from
the chassis, first from the rear and then from the front:
Removing the Power Supplies Before Installing the MX240 Router without a
1.
Lift on page 181
Removing the Fan Tray Before Installing the MX240 Router without a Lift on page 182
2.
Removing the SCBs Before Installing the MX240 Router without a Lift on page 183
3.
Removing the DPCs Before Installing the MX240 Router without a Lift on page 184
4.
Removing the FPC Before Installing the MX240 Router without a Lift on page 185
5.
Remove the leftmost power supply first and then work your way to the right. To remove
the AC or DC power supplies (see
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
1.
the strap to an approved site ESD grounding point. See the instructions for your site.
Chapter 16: Installing the MX240 Router
Figure 61 on page
182):
181