Table 68: Mx240 Common Component Power Requirements; Table 69: Fru Power Requirements - Juniper mx240 Hardware Manual

Universal edge router
Hide thumbs Also See for mx240:
Table of Contents

Advertisement

Table 68: MX240 Common Component Power Requirements

Component
Base system
Normal-capacity cooling system
High-capacity cooling system

Table 69: FRU Power Requirements

Component
Switch Control Boards (SCBs)
SCB
SCBE
SCBE2
Routing Engines
Routing Engines
Fixed Configuration MPCs
Copyright © 2016, Juniper Networks, Inc.
NOTE:
The power for the cooling system comes from a different tap on the
power supply, reserved for the cooling system only. The cooling system power
requirement does not need to be deducted from the output power budget
of the power supply.
Part Number
SCB-MX960 (applies to MX240,
MX480, and MX960)
SCBE-MX (applies to MX240, MX480,
and MX960)
SCBE2-MX (applies to MX240,
MX480, and MX960)
RE-S-1300-2048
RE-S-1800X2-8G
RE-S-1800X4-8G
RE-S-1800X2-16G
RE-S-1800X4-16G
RE-S-1800X4-32G
RE-S-2000-4096
RE-S-X6-64G
Chapter 12: AC Power Requirements and Specifications
Maximum Power Requirement (Watts)
40 W
70 W
85 W
Maximum Power Requirement
150 W
160 W at 55° C
130 W at 40° C
120 W at 25° C
185 W at 55° C
160 W at 40° C
155 W at 25° C
90 W