Figure 66: Installing The Router In The Rack - Juniper mx240 Hardware Manual

Universal edge router
Hide thumbs Also See for mx240:
Table of Contents

Advertisement

Related
Documentation
Copyright © 2016, Juniper Networks, Inc.
With one person on each side, hold onto the bottom of the chassis and carefully lift
3.
it onto the mounting shelf.
WARNING:
To prevent injury, keep your back straight and lift with your
legs, not your back. Avoid twisting your body as you lift. Balance the load
evenly and be sure that your footing is solid.
Slide the router onto the mounting shelf until the mounting brackets contact the rack
4.
rails. The shelf ensures that the holes in the mounting brackets of the chassis align
with the holes in the rack rails.
Install a mounting screw into each of the open mounting holes aligned with the rack,
5.
starting from the bottom.
Visually inspect the alignment of the router. If the router is installed properly in the
6.
rack, all the mounting screws on one side of the rack should be aligned with the
mounting screws on the opposite side and the router should be level.

Figure 66: Installing the Router in the Rack

NOTE:
This illustration depicts the router being installed in an open-frame
rack. For an illustration of the mounting hardware required for a four-post
rack or cabinet, see
MX240 Site Preparation Checklist on page 105
Tools Required to Install the MX240 Router without a Mechanical Lift on page 181
Chapter 16: Installing the MX240 Router
Figure 48 on page
166.
187