Black Banding (At Right Angle With The Feeding Direction) - Toshiba e-STUDIO205L Service Handbook

Hide thumbs Also See for e-STUDIO205L:
Table of Contents

Advertisement

6.4.13

Black banding (at right angle with the feeding direction)

Defective area
Main charger
Fuser unit
High-voltage transformer
(Main charger / Developer
bias / Transfer roller unit)
Drum
Scanner
© 2009 TOSHIBA TEC CORPORATION All rights reserved
Fig. 6-14
Step
Check items
1
Is the needle electrode dirty or
deformed?
2
Are the fuser roller, separation finger
for fuser roller and thermistor dirty?
3
Has the fuser roller and separation
finger for fuser roller reached their
PM life?
4
Is the high-voltage transformer
output defective?
5
Is there a deep scratch on the drum
surface?
6
Is there thin scratch (drum pitting) on
the drum surface?
7
Is there a foreign matter on the
carriage rail?
6 - 133
Prescription
Clean or replace the needle
electrode.
Clean them.
Replace them.
Adjust the output, or replace the
transformer.
Replace the drum if the scratch has
reached the aluminum base.
Check and adjust the contact
condition of the cleaning blade and
recovery blade.
Remove the foreign matter.
e-STUDIO205L/255/305/355/455
ERROR CODE AND TROUBLESHOOTING
6