Setting Codes - Toshiba e-STUDIO205L Service Handbook

Hide thumbs Also See for e-STUDIO205L:
Table of Contents

Advertisement

2.7.2

Setting codes

Notes:
The digit after the hyphen in "Code" of the following table is a sub code.
In "Board", the SRAM of the board in which the data of each code is stored is indicated. "M"
stands for the LGC board, "SYS", "NIC" and "UTY" stands for the SYS board.
Classific
Code
ation
200
General
Date and time setting
201
General
Destination selection
202
User
Counter installed
interface
externally
203
General
Line adjustment mode
204
User
Auto-clear timer setting
interface
205
User
Auto power save mode
interface
timer setting
e-STUDIO205L/255/305/355/455
SELF-DIAGNOSIS MODES
Setting mode (08)
Functi
Items
on
ALL
ALL
ALL
ALL
ALL
ALL
2 - 62
Default
Boa
<Acceptable
rd
value>
-
-
Year/month/date/day/
<13 digits>
hour/minute/second
Example:
03 07 0 13 13 27 48
"Day" - "0" is for
"Sunday". Proceeds
Monday through
Saturday from "1" to
"6".
EUR: 0
M
0: EUR
UC: 1
1: UC
JPN: 2
2: JPN
<0-2>
0
M
0: No external counter
<0-4>
1: Coin controller
2: Copy key card
(This value is valid
only when "2" is set
to 08-201.)
3: Key copy counter
4: Key card for OEM1
0
M
0: For factory
<0-1>
shipment
1: For line
*
Field: "0" must be
selected
3
SYS Timer to return the
<0-10>
equipment to the
default settings when
the [START] button is
not pressed after the
function and the mode
are set
0: Not cleared
1 to 10:Set number x 15
4
SYS Timer to automatically
<0-15>
switch to the Auto
power save mode when
the equipment has not
been used
0: Invalid
4: 1min.
5: 2min.
7: 4min.
8: 5min.
9: 7min.
10: 10min.
11: 15min.
12: 20min.
13: 30min.
14: 45min.
15: 60min.
© 2009 TOSHIBA TEC CORPORATION All rights reserved
Proce
Contents
dure
5
1
1
1
1
sec.
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio455E-studio255E-studio305E-studio355

Table of Contents