<Adjustment procedure>
(1)
Loosen screw A. Remove screw B and
temporarily fix it to position C.
(2)
Adjust the position of the stay with the scale
according to the dogleg image and tighten
screws A and C.
Dogleg image A
Perform adjustment so that the stay of the
fuser unit comes below the center line of
the scale.
Dogleg image B
Perform adjustment so that the stay of the
fuser unit comes above the center line of
the scale.
© 2009 TOSHIBA TEC CORPORATION All rights reserved
Fig. 3-111
A
C
Fig. 3-112
A
C
Fig. 3-113
3 - 95
A
C
B