3.5.3

Gamma balance adjustment

The density is adjusted by adjusting the gamma balance. The adjustment is performed by selecting its
density area from the following: low density, medium density and high density.
Color
Smooth
Detail
mode
(PS)
(PS)
Black
7315-0
7316-0
7315-1
7316-1
7315-2
7316-2
Note:
Changing the adjustment setting influences the adjacent density area slightly.
E.g.: When the value of the medium density is larger, the adjacent areas in the low density and
high density range will become slightly darker.
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Key in the codes to be adjusted (language and screen) and press the [START] button.
(3)
Key in the value corresponding to the density area to be adjusted (0, 1 or 2) and press the
[START] button.
0: Low density 1: Medium density 2: High density
(4)
Key in the adjustment value. (To correct the value once keyed in, press the [CLEAR] button.)
Press the [ENTER] or [INTERRUPT] button to store the value in memory. → The equipment
(5)
goes back to the ready state.
(6)
For resetting the value, repeat step (2) to (5).
(7)
Turn the power OFF and then back ON. Then perform printing.
(8)
If the image density has not been attained, repeat step (2) to (7).
e-STUDIO205L/255/305/355/455
ADJUSTMENT
Language and screen
Smooth
Detail
Smooth
(PCL)
(PCL)
(XPS)
7317-0
7318-0
7319-0
7317-1
7318-1
7319-1
7317-2
7318-2
7319-2
3 - 30
<Adjustment Mode (05)>
Item to
be
Detail
adjusted
(XPS)
7320-0
Low
The larger the value is,
density
the density of the item
to be adjusted
7320-1
Medium
becomes darker.
density
Acceptable values: 0
7320-2
High
to 255
density
(Default: 128)