5.7

Preventive Maintenance Checklist

The following is the check items of each unit at preventive maintenance.
Symbols/Values used in the checklist
Cleaning
A: Clean with alcohol
L: Launa 40
B: Clean with soft pad,
SI: Silicon oil
cloth or vacuum
W1: White grease (Molykote EM-
cleaner
W2: White grease (Molykote HP-
AV: Alvania No.2
FL: Floil (GE-334C)
CG: Conductive grease (KS-660)
Notes:
Perform cleaning and lubricating in the following timing. Lubricate the replacement parts
according to the replacement cycle.
- e-STUDIO205L: every 80,000 sheets
- e-STUDIO255: every 100,000 sheets
- e-STUDIO305: every 120,000 sheets
- e-STUDIO355: every 125,000 sheets
- e-STUDIO455: every 150,000 sheets
Values under "Replacement" indicate the replacement cycle for the e-STUDIO205L/255/305/
355/455.
The replacement cycle of the parts in the feeding section equals to the number of sheets fed
from each paper source.
Be careful not to put oil on the rollers, belts and belt pulleys when lubricating.
© 2009 TOSHIBA TEC CORPORATION All rights reserved
Lubrication/Coating
30L)
300)
5 - 17
Replacement
Value: Replacement
cycle
R: Replace if
deformed or
damaged
e-STUDIO205L/255/305/355/455
PREVENTIVE MAINTENANCE (PM)
Operation check
After cleaning or
replacement, confirm
there is no problem.
5