3.5.2

Adjustment of image density

The image density level can be set at the following codes.
Toner mode
General
Toner save
672-0 to 4
7352-0 to 4
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Key in a code and press the [START] button.
(3)
Key in the sub code (0, 1, 2, 3 or 4), and press the [START] button.
(4)
Key in an adjustment value.
(To correct the keyed-in value, press the [CLEAR] button.)
(5)
Press the [ENTER] or [INTERRUPT] button to store the value in memory. The equipment goes
back to the ready state.
(6)
For resetting the value, repeat step (2) to (5).
(7)
Turn the power OFF and then back ON to perform printing job.
(8)
If the desired image density has not been attained, repeat step (2) to (7).
© 2009 TOSHIBA TEC CORPORATION All rights reserved
Item to be
Hardcopy
adjusted
security
printing
7351-0 to 4
Adjustment of
image density
3 - 29
< Adjustment Mode (05) >
Remarks
When the value is decreased, text becomes
lighter.
Acceptable values: 0 to 10
Notes:
1. Set not to reverse the large and
small number of the setting value
corresponding to the sub code.
Ex.) When the image density
level for 672-0, 672-1, 672-2,
672-3, and 672-4 is assumed to
be "A","B", "C", "D", and "E"
respectively, they should have the
following correlation:
A
B
C
D
E
2. Remember that the image
specifications and life span of the
replacing parts may not meet the
standard when the setting value
is changed from the default value.