Toshiba e-STUDIO205L Service Handbook page 599

Hide thumbs Also See for e-STUDIO205L:
Table of Contents

Advertisement

Processing status
0% or above
15% or above
30% or above
45% or above
60% or above
75% or above
90% or above
(7)
After the update is completed properly, the LED on the download jig blinks slowly (at interval of
0.8 sec). The LED starts blinking in approx. 30 sec. (finisher section) or 2 min. 30 sec. (saddle
stitcher section) since the update starts. It is assumed that the update is failed if it does not start
blinking even though 1 min. has passed (finisher section) or 3 min. (saddle stitcher section), or
LED flashes fast (at interval of 0.1 sec.). In this case, turn OFF the power and check the following
items. Then, clear the problem and restart updating from the beginning.
Is the download jig connected properly?
Is the ROM installed to the download jig properly?
Is the updating data written on the ROM of the download jig properly?
Do the download jig and the equipment operate properly?
Is the DIP switch on the finisher control PC board set properly according to the download
section (finisher or saddle stitcher)?
(8)
Press the [ON/OFF] button on the control panel and turn the power OFF using the main power
switch and remove the download jig.Return the DIP switch to the status before updating.
(9)
Install the finisher rear cover.
[B] Confirmation of the updated data
After the updating is completed, check each data version in Setting Mode (08) to confirm that the data
were overwritten properly.
P.8-50 "8.4 Confirmation of the updated data"
© 2009 TOSHIBA TEC CORPORATION All rights reserved
LED
LED103
LED102
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
8 - 37
LED101
ON
OFF
ON
OFF
ON
OFF
ON
e-STUDIO205L/255/305/355/455